{"id":2410,"date":"2017-11-05T21:33:54","date_gmt":"2017-11-05T21:33:54","guid":{"rendered":"http:\/\/areton-ltd.com\/?page_id=2410"},"modified":"2020-03-23T17:04:21","modified_gmt":"2020-03-23T17:04:21","slug":"three-in-one-hifu-manual","status":"publish","type":"page","link":"https:\/\/areton-ltd.com\/Aretonoldbackup\/three-in-one-hifu-manual\/","title":{"rendered":"Three in one HIFU Manual"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space][vc_single_image image=&#8221;7215&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; style=&#8221;vc_box_outline&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/areton-ltd.com\/product\/3-in-1-hifu\/&#8221;][vc_empty_space][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;6390&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/areton-ltd.com\/quiz\/3-in-1\/&#8221;][vc_btn title=&#8221;Take Test now and get your certification&#8221; color=&#8221;danger&#8221; size=&#8221;lg&#8221; align=&#8221;center&#8221; link=&#8221;url:http%3A%2F%2Fareton-ltd.com%2Fquiz%2F3-in-1%2F|||&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;6295&#8243; img_size=&#8221;full&#8221; style=&#8221;vc_box_outline&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/www.youtube.com\/channel\/UCAKMKWmwxEVL74f5szpnLUg\/videos&#8221;][vc_single_image image=&#8221;6297&#8243; img_size=&#8221;full&#8221; style=&#8221;vc_box_outline&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/areton-ltd.com\/contact\/&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][vc_column_text]<\/p>\n<h2>Table Content<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Content<\/th>\n<th>Links<\/th>\n<\/tr>\n<tr>\n<td>Warnings and Disclaimer<\/td>\n<td><a href=\"#warnings-and-disclaimer\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Device Main Parameters<\/td>\n<td><a href=\"#device-parameters\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Main Unit Front and Back Introduction<\/td>\n<td><a href=\"#main-unit-front-and-back\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Accessories Description<\/td>\n<td><a href=\"#accessories-description\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Face and body Handle Description<\/td>\n<td><a href=\"#face-and-body-handle-description\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Cartridge Description<\/td>\n<td><a href=\"#cartridge-description\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Cartridge Information<\/td>\n<td><a href=\"#Cartridge-Information\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Vaginal Handle And Cartridges<\/td>\n<td><a href=\"#vaginal-handle-and-cartridge\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Introduction to the device user interface<\/td>\n<td><a href=\"#introduction-device-user-interface\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Face Skin Tightening and Body Contouring User Interface<\/td>\n<td><a href=\"#face-skin-user-interface\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>System General Advice For Face and Body Contouring<\/td>\n<td><a href=\"#general-advice-for-face-and-body\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Guidelines for Face HIFU Treatment<\/td>\n<td><a href=\"http:\/\/areton-ltd.com\/multiline-hifu-machine\/#About-Perspex-Test\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Guidelines for Neck Treatment<\/td>\n<td><a href=\"#guidelines-for-neck-treatment\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Introduction to HIFU Vaginal Tightening<\/td>\n<td><a href=\"#introduction-hifu-vaginal-tightening\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Key Device Parameters<\/td>\n<td><a href=\"#key-device-parameters\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Vaginal Tightness Measurement Interface<\/td>\n<td><a href=\"#vaginal-tightness-measurement-interface\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Vaginal User Interface<\/td>\n<td><a href=\"#vaginal-user-interface\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Vaginal Tightening Treatment Routine<\/td>\n<td><a href=\"#vaginal-tightening-treatment-routine\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Notes for use and maintenance<\/td>\n<td><a href=\"#maintenance-notes\">Read More<\/a><\/td>\n<\/tr>\n<tr>\n<td>Troubleshooting<\/td>\n<td><a href=\"#troubleshooting\">Read More<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1580129099940{border-bottom-width: 2% !important;}&#8221;][vc_column][vc_single_image image=&#8221;6198&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1576760695183{background-image: url(https:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/dot.png?id=5185) !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Overview of Device<\/h2>\n<p class=\"white\">The 3 in 1 HIFU (<em>High-Intensity Focused Ultrasound)\u00a0<\/em>device is equipped with cutting edge technology that allows having more accurate sculpting of face and body and vagina tightening. The advanced cosmetic technology of the device can significantly tighten and lift several areas of the face, reduce the signs of aging and improve the tone of the skin in a single session, with potentially long-lasting effects. There are no incisions or major injuries to the surface of the skin.<\/p>\n<p class=\"white\">Ths Device intended uses are only Aesthetic, no medical claims are made at any point This device is only intended to improve the lifestyle of the individual and his\/her appearance. No claims of curing disease are made on this device.\u00a0 This instruction manual provides a description of this HIFU System, its controls and displays. Instructions for its basic operation and other information important to the user. Detailed clinical use of the device is provided separately. The Information in this manual is intended solely for the devices manufactured by Areton Ltd and Areton Ltd\u2019s Clients.<\/p>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_empty_space][vc_video link=&#8221;https:\/\/youtube.com\/embed\/PWZwwmYIoBQ&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h3>Device Tour<\/h3>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;10px&#8221;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/Fib0XSAoM_c&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h3>Body treatment demonstration<\/h3>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;10px&#8221;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/FAhQosm9eYE&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3>Hifu Vaginal Rejuvenation<\/h3>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;10px&#8221;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/eWgD3SWYygI&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3>Body Treatment<\/h3>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;10px&#8221;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/vQ3Qz4O-wHk&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558639425986{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/dot.png?id=5185) !important;}&#8221; el_id=&#8221;warnings-and-disclaimer&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Warnings and Disclaimer<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<p class=\"white\">Despite the information provided in this manual the user has to always exercise caution in the use of these types of Devices. This is due to the ablative power of professional High-Intensity Focused Ultrasound devices. Failure to exercise caution can result in injuries. This device intended uses are merely aesthetic, no claims of fat loss are made with this device. <strong>Do not use this device on the upper eyelids, this could cause permanent injuries to the eye.<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Ablative Power of Professional HIFU Devices<\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<p class=\"white\">Despite the claims of \u201ccomplete safety\u201d made by some manufacturers about their professional HIFU Devices, the ablative power of these types of devices must not be underestimated. The power delivered by professional HIFU devices can bend the surface and produce dents onto pieces of hard perspex, this provides an idea of the ablating power of these devices. For these reasons the aesthetic practitioner has to exercise caution in the use of these powerful devices.<\/p>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;device-parameters&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Device Main Parameters<\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<table style=\"border-collapse: collapse; width: 100%; height: 144px;\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Main Device Size<\/td>\n<td style=\"width: 50%; height: 24px;\">\u00a040*38*25cm<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Input Frequency<\/td>\n<td style=\"width: 50%; height: 24px;\">\u00a050Hz\/60Hz<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Approximate Power Output<\/td>\n<td style=\"width: 50%; height: 24px;\">\u00a00.2J-2.0J<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Headpieces<\/td>\n<td style=\"width: 50%; height: 24px;\">\u00a0Vagina tightening Cartridges (3.0mm,4.5mm);\u00a0Face lifting Cartridges (1.5mm,3.0mm,4.5mm);<\/p>\n<p>Body Contouring Cartridges (8.0mm,13.0mm)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Voltage<\/td>\n<td style=\"width: 50%; height: 24px;\">\u00a0Single phase AC110V-240V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Device total weight<\/td>\n<td style=\"width: 50%; height: 24px;\">\u00a0About 35 kg Including Casing For Transport<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;main-unit-front-and-back&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Main Unit Front and Back Introduction<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner][vc_single_image image=&#8221;6176&#8243; img_size=&#8221;full&#8221;][vc_column_text]<\/p>\n<h3 style=\"text-align: center;\">Areton 3 in 1 Hifu Training and Treatment in South Africa<\/h3>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/eiV0S-5Hq_Y&#8221; el_aspect=&#8221;43&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/wTu1MWIVeVQ&#8221; el_aspect=&#8221;43&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558640814816{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/dot.png?id=5185) !important;}&#8221; el_id=&#8221;accessories-description&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Accessories description<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<strong class=\"white\">Face and Body Handle with 3.0 mm Cartridge.<\/strong>[\/vc_column_text][vc_single_image image=&#8221;6177&#8243; img_size=&#8221;full&#8221; style=&#8221;vc_box_outline&#8221; border_color=&#8221;white&#8221;][vc_empty_space][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<strong class=\"white\">Face and Body Handle<\/strong>[\/vc_column_text][vc_single_image image=&#8221;6178&#8243; img_size=&#8221;full&#8221; style=&#8221;vc_box_outline&#8221; border_color=&#8221;white&#8221;][vc_empty_space][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;face-and-body-handle-description&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Face and body Handle Description<\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<table style=\"border-collapse: collapse; width: 99.9519%; height: 144px;\">\n<tbody>\n<tr style=\"height: 24px; background: #e1114c; color: #fff; font-size: 20px; font-weight: bold;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Item<\/td>\n<td style=\"width: 49.9519%; height: 24px;\" width=\"283\">\u00a0Description<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Switch button<\/td>\n<td style=\"width: 49.9519%; height: 24px;\">\u00a0Press to fire the ultrasonic shots<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Work button<\/td>\n<td style=\"width: 49.9519%; height: 24px;\">\u00a0The indicator light will light up while shots are being fired.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Cartridge Lock Sleeve<\/td>\n<td style=\"width: 49.9519%; height: 24px;\">\u00a0Locks the cartridges to the handle.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Cartridges<\/td>\n<td style=\"width: 49.9519%; height: 24px;\">\u00a0Different cartridges work at different depths.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px;\">\u00a0Cable sheathing<\/td>\n<td style=\"width: 49.9519%; height: 24px;\">\u00a0Connect the handle to the device.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Face and Body Cartridges<\/h2>\n<p>[\/vc_column_text][vc_single_image image=&#8221;2501&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Detail of a 4.5mm Face and Body Cartridge<\/h2>\n<p>[\/vc_column_text][vc_single_image image=&#8221;2421&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/TsJ_i1sfZPE&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/pZyI9xVpqtA&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row el_id=&#8221;cartridge-description&#8221;][vc_column][vc_column_text]<\/p>\n<h2><strong>Cartridge Description<\/strong><\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\">\u00a0Item<\/td>\n<td style=\"width: 50%;\">\u00a0Description<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\u00a0Top marker<\/td>\n<td style=\"width: 50%;\">\u00a0Cartridges Transducers.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\u00a0Ultrasonic line length<\/td>\n<td style=\"width: 50%;\">Maximum line length.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h2>Cartridges Types For Face Lifting<\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<table border=\"1\" width=\"909\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"142\" \/>\n<col width=\"85\" \/>\n<col width=\"113\" \/>\n<col width=\"114\" \/>\n<col width=\"113\" \/> <\/colgroup>\n<tbody>\n<tr valign=\"TOP\">\n<td width=\"142\" height=\"20\">\n<p align=\"CENTER\">Cartridges transducer<\/p>\n<\/td>\n<td width=\"85\">\n<p align=\"CENTER\">Frequency<\/p>\n<\/td>\n<td width=\"113\">\n<p align=\"CENTER\">Treatment Depth<\/p>\n<\/td>\n<td width=\"114\">\n<p align=\"CENTER\">Spots Distance<\/p>\n<\/td>\n<td width=\"113\">Maximum Length<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"142\" height=\"21\">\n<p align=\"CENTER\">DS 7-1.5N<\/p>\n<\/td>\n<td width=\"85\">\n<p align=\"CENTER\">7MHz<\/p>\n<\/td>\n<td width=\"113\">\n<p align=\"CENTER\">1.5mm<\/p>\n<\/td>\n<td width=\"114\">\n<p align=\"CENTER\">1-0.6mm<\/p>\n<\/td>\n<td width=\"113\">15mm<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"142\" height=\"21\">\n<p align=\"CENTER\">DS 7-3.0N<\/p>\n<\/td>\n<td width=\"85\">\n<p align=\"CENTER\">7MHz<\/p>\n<\/td>\n<td width=\"113\">\n<p align=\"CENTER\">3.0mm<\/p>\n<\/td>\n<td width=\"114\">\n<p align=\"CENTER\">1-0.6mm<\/p>\n<\/td>\n<td width=\"113\">25mm<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"142\" height=\"20\">\n<p align=\"CENTER\">DS4-4.5N<\/p>\n<\/td>\n<td width=\"85\">\n<p align=\"CENTER\">4MHz<\/p>\n<\/td>\n<td width=\"113\">\n<p align=\"CENTER\">4.5mm<\/p>\n<\/td>\n<td width=\"114\">\n<p align=\"CENTER\">1-0.6mm<\/p>\n<\/td>\n<td width=\"113\">25mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558639600379{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/dot.png?id=5185) !important;}&#8221; el_id=&#8221;vaginal-handle-and-cartridge&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<p class=\"white\">The picture below illustrates the distance between the furthest dots created on the perspex provided. This distance between A and B can be adjusted on the user interface if required. This is done when the area treated is particularly small live lip area or eyelid area using the 1.5 mm cartridge.<\/p>\n<p>[\/vc_column_text][vc_column_text]<img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-2495\" src=\"https:\/\/i0.wp.com\/areton-ltd.com\/wp-content\/uploads\/2017\/11\/perspex-2-300x250.jpg?resize=300%2C250&#038;ssl=1\" alt=\"\" width=\"300\" height=\"250\" srcset=\"https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/perspex-2.jpg?resize=300%2C250&amp;ssl=1 300w, https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/perspex-2.jpg?w=580&amp;ssl=1 580w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"white\">The maximum distance between A and B is indicated on the Cartridge. This distance can be varied by changing the appropriate parameter in the user interface.<\/p>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Vaginal Handle and the two Cartridges<\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<figure id=\"attachment_2491\" class=\"wp-caption alignleft\" style=\"width: 600px;\" aria-describedby=\"caption-attachment-2491\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"489\" class=\"wp-image-2491 size-full\" src=\"https:\/\/i0.wp.com\/areton-ltd.com\/wp-content\/uploads\/2017\/11\/HTB1phMXPXXXXXaXXpXXq6xXFXXXH.jpg?resize=600%2C489\" srcset=\"https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/HTB1phMXPXXXXXaXXpXXq6xXFXXXH.jpg?w=600&amp;ssl=1 600w, https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/HTB1phMXPXXXXXaXXpXXq6xXFXXXH.jpg?resize=300%2C245&amp;ssl=1 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<p>Vaginal Tightening Handle with 3.0 mm and 4.5 mm Cartridges.<\/p>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Vaginal Ultrasound Transducer or Cartridge<\/h2>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]The device comes with two Vaginal cartridges as a standard. 4.5 mm and 3.0 mm in depth respectively. Usually both cartrides are used in the Vaginal tightening treatment.[\/vc_column_text][vc_single_image image=&#8221;6181&#8243; img_size=&#8221;full&#8221;][vc_empty_space][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Vaginal Tightness Measurer<\/h2>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]The main purpose of Vaginal HIFU treatment is to improve the sexual life quality of the individual. Therefore, the vaginal tightness measure is a very useful tool because it makes it possible for the aesthetic professional to provide an estimation of the vaginal tightness before and after the treatment.[\/vc_column_text][vc_single_image image=&#8221;6182&#8243; img_size=&#8221;full&#8221;][vc_empty_space][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558639642785{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/dot.png?id=5185) !important;}&#8221; el_id=&#8221;introduction-device-user-interface&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Introduction to the device user interface<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<p class=\"white\">Click on the user interface to enter the next interface (Choose treatment type). As shown in the picture below there are two visible options, a face, and a vaginal picture.\u00a0 To start the device in order for face and body contouring treatment click on the picture of the face. The software detects automatically which cartridge you are placing in the handle and depending on the depth of the respective cartridge it selects the type of software required, either face treatment or body contouring. For example, if you place the 1.5 mm, 3.0 mm and 4.5mm cartridges the software will show you the picture of the face where the treatment has to be carried out.\u00a0 In case you place the 8.0 mm or the 13.0 mm cartridge the software will show you the parts of the body where you can apply the HIFU treatment for each respective cartridge.<\/p>\n<p class=\"white\">To summarise,\u00a0 in the case of<\/p>\n<ul>\n<li class=\"white\">face treatment click on the face icon and insert the face cartridges, 1.5 mm, 3.0 mm or 4.5 mm<\/li>\n<li class=\"white\">\u00a0body treatment click on the face icon and\u00a0 insert the 8.0 mm or 13.0 mm cartridges<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;2422&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;face-skin-user-interface&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Face Skin Tightening and Body Contouring User Interface<\/h2>\n<p>[\/vc_column_text][vc_empty_space][vc_single_image image=&#8221;6185&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;general-advice-for-face-and-body&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>System General Advice\u00a0For Face and Body Contouring<\/h2>\n<p>[\/vc_column_text][vc_column_text]Check if the handle and connector are making good contact. Make sure the cartridge is correctly identified by the user interface Do not place the handle or cartridge on the floor or other hard surfaces, always use the dedicated hook on the unit. Do not twist the handle cable to avoid damaging the internal wires<\/p>\n<p>During its device normal operation only utilizes ultrasound conductive gels, do not use other lubricants or emulsions like especially oils, Avoid damage to the cartridge or circuit.<\/p>\n<p>The cartridges have a memory function, After use, please store it separately away from the magnetic card or static-charged object.<\/p>\n<p>Do not insert objects other than the cartridges into the handle, otherwise the system circuitry may be damaged.<br \/>\n<a name=\"hifutreament\"><\/a>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558639777113{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/dot.png?id=5185) !important;}&#8221; el_id=&#8221;guidelines-for-face-hifu-treatment&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Guidelines for Face HIFU Treatment<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<p class=\"white\">There is not hard and fast rule in the way the HIFU face treatment has to be carried out. In general, the higher overall energy delivered into the skin the better the skin tightening effects. This is because the higher the energy delivered the better the collagen regeneration effects.\u00a0 By all means, certain areas of the face should be avoided for safety reasons. This is because the HIHU devices have fundamentally ablative effects at deep levels of the skin therefore certain areas of the face were certain organs (like throat, nerves or bones, etc) should be avoided.<\/p>\n<p class=\"white\">There are three cartridges indicated for face HIFU treatment:<\/p>\n<ul>\n<li class=\"white\">4.5 mm in depth<\/li>\n<li class=\"white\">3.0 mm in depth and<\/li>\n<li class=\"white\">1.5 mm in depth<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;2499&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_column_text]The Aesthetic practitioner should use all the three cartridges during every HIFU face treatment to ensure the High-Intensity Ultrasound Energy is delivered to all three depths in the skin. This will ensure the best collagen regeneration at the three levels of the skin.\u00a0 In any case, please bear in mind that each cartridge can only be used in certain areas of the face, while others should be avoided. Once the cartridge is inserted into the handle, the soft<a href=\"https:\/\/i0.wp.com\/areton-ltd.com\/wp-content\/uploads\/2017\/11\/face-treatment-2.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2426 alignright\" src=\"https:\/\/i0.wp.com\/areton-ltd.com\/wp-content\/uploads\/2017\/11\/face-treatment-2.jpg?resize=291%2C259\" alt=\"\" width=\"291\" height=\"259\" \/><\/a>ware provides clear indications of the areas in the face where the treatment with the respective cartridge is allowed.\u00a0 Also, the Software displays the maximum number of shots per area, but this should be used as an overall indication only.<\/p>\n<p>Generally, the aesthetic practitioner has to start the treatment using the deepest depth, the 4.5 mm cartridge, followed by the 3.0 mm and finally by the 1.5 mm cartridge.<\/p>\n<p>When placing each face cartridge on the handle the screen will display the areas of the face where the treatment is permissible at the type of cartridge you are using, in the picture below, for example, you can see the area on the face where the cartridge 1.5 mm in depth can be used.[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_column_text]The video Below shows you a training session for the Areton Portable HIFU. This is a useful video to watch because this training session goes through the main safety points in Face HIFU treatment which are the same as the safety indications for the Areton 3 in 1 HIFU. Therefore it is recommendable you take your time to watch the following video in its entirety.[\/vc_column_text][vc_video link=&#8221;https:\/\/youtube.com\/embed\/UaNgSHnTVjA&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;guidelines-for-neck-treatment&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Guidelines for Neck Treatment<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner][vc_column_text]The neck is a delicate area, therefore it has to be treated with particular care.\u00a0 The throat must\u00a0<strong>not<\/strong> be treated by the HIFU device. This is because the throat organ is located on the superficial area of the skin in the neck, therefore any ablative ultrasonic treatment could cause unnecessary traumas to the thyroid gland and the throat.<\/p>\n<p><a name=\"vaginaltightening\"><\/a>[\/vc_column_text][vc_single_image image=&#8221;6191&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558639869199{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/bg-square-1.png?id=5188) !important;}&#8221; el_id=&#8221;introduction-hifu-vaginal-tightening&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Introduction to HIFU Vaginal Tightening<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner][vc_column_text]The same principle which applies to HIFU skin tightening applies also to vaginal tightening. One of the advantages of HIFU Vaginl tightening are low risks to the individual. The treatment is non-invasive and non-surgical, it causes no wound, no scars can tighten the vagina effectively proving women sexual life.<\/p>\n<p>&nbsp;<\/p>\n<p>The sound cartridge will deliver shots to the vaginal internal walls at the depth of 3.0 mm and 4.5 mm. This will cause a tightening of the Vaginal internal walls and improve the subject of sexual life and sexual sensitivity in general.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;key-device-parameters&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Key Device Parameters<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<table border=\"1\" width=\"568\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr valign=\"TOP\">\n<td width=\"283\" height=\"20\">Frequency<\/td>\n<td width=\"283\">50-60Hz<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"283\" height=\"21\">Maximum power<\/td>\n<td width=\"283\">200w<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"283\" height=\"21\">Treatment cartridges<\/td>\n<td width=\"283\">3.0mm 4.5mm<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"283\" height=\"21\">Optional Cartridge<\/td>\n<td width=\"283\">1.5mm<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"283\" height=\"21\">Input Voltage<\/td>\n<td width=\"283\">110v-220v<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"283\" height=\"20\">Packing size<\/td>\n<td width=\"283\">69*64*34cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558639934702{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/dot.png?id=5185) !important;}&#8221; el_id=&#8221;vaginal-tightness-measurement-interface&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2 class=\"white\">Vaginal Tightness Measurement Interface<\/h2>\n<p>[\/vc_column_text][vc_empty_space][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<p class=\"white\">Tighten the switch of the pressure before the test, Extrusion airbag to increase the value, and then adjust the switch of the pressure until the value on screen around 20.<\/p>\n<p>[\/vc_column_text][vc_column_text][\/vc_column_text][vc_column_text]<\/p>\n<table border=\"1\" width=\"568\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr valign=\"TOP\">\n<td bgcolor=\"#7e7e7e\" width=\"188\" height=\"41\">\n<p style=\"text-align: center; color: #fff;\" align=\"RIGHT\">Pressure Value Measured<\/p>\n<\/td>\n<td style=\"text-align: center; color: #fff;\" bgcolor=\"#7e7e7e\" width=\"189\">Condition of vaginal tightening<\/td>\n<td bgcolor=\"#7e7e7e\" width=\"189\">\n<p style=\"text-align: center; color: #fff;\" align=\"CENTER\">Vaginal Sensitivity<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"21\">\n<p style=\"color: #fff;\" align=\"CENTER\">Under 60<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Very bad<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #ffff;\" align=\"CENTER\">None<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"21\">\n<p style=\"color: #ffff;\" align=\"CENTER\">60-80<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Relatively bad<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Low<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"21\">\n<p style=\"color: #fff;\" align=\"CENTER\">80-120<\/p>\n<\/td>\n<td style=\"color: #fff;\" width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Normal<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #ffff;\" align=\"CENTER\">Acceptable<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"21\">\n<p style=\"color: #fff;\" align=\"CENTER\">120-160<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Good<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Very Good<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"20\">\n<p style=\"text-align: center; color: #fff;\" align=\"RIGHT\">Above 160<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Very good<\/p>\n<\/td>\n<td width=\"189\">\n<p style=\"color: #fff;\" align=\"CENTER\">Excellent<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;vaginal-user-interface&#8221;][vc_column][vc_column_text]<\/p>\n<h2>Vaginal User Interface<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;6194&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<table class=\"alignleft\" border=\"1\" width=\"568\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"20\">\n<p align=\"CENTER\">Accessory<\/p>\n<\/td>\n<td width=\"189\">\n<p align=\"CENTER\">Accessory Picture<\/p>\n<\/td>\n<td width=\"189\">Brief Explanation<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"146\">3.0 mm Cartridge<\/td>\n<td rowspan=\"2\" width=\"189\">\u00a0<img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2430\" src=\"https:\/\/i0.wp.com\/areton-ltd.com\/wp-content\/uploads\/2017\/11\/vaginal.jpg?resize=88%2C120\" alt=\"\" width=\"88\" height=\"120\" \/><\/td>\n<td width=\"189\">\n<p align=\"JUSTIFY\">The ultrasound reaches the mucous tissue directly to speed the cell activity, Helping superficial collagen regeneration and\u00a0 increasing overall tissue elasticity<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"208\">4.5 mm Cartridge<\/td>\n<td width=\"189\">\n<p align=\"JUSTIFY\">The power reaches a deeper\u00a0 layer\u00a0better helping vaginal muscle layer to recover elasticity; contributing to an overall tighter Vaginal internal wall.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"188\" height=\"61\">Pressure tester<\/td>\n<td width=\"189\">\u00a0<img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2429\" src=\"https:\/\/i0.wp.com\/areton-ltd.com\/wp-content\/uploads\/2017\/11\/pressure-tester.jpg?resize=97%2C46\" alt=\"\" width=\"97\" height=\"46\" \/><\/td>\n<td width=\"189\">Insert\u00a0the smallest\u00a0ribbed balloon into the Vagina. Pump and look at the user interface to take the pressure measurement.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1558639981958{background-image: url(http:\/\/areton-ltd.com\/wp-content\/uploads\/2019\/04\/bg-square-1.png?id=5188) !important;}&#8221; el_id=&#8221;vaginal-tightening-treatment-routine&#8221;][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h2>Vaginal Tightening Treatment\u00a0Routine<\/h2>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<ul>\n<li>Sterilize the Vaginal Pressure tester with a sterilizing product, this is important to prevent cross infections. Then insert the pressure measuring gouge into the vagina and record the value measured to check for future improvements of the Vaginal Tightness. Repeat the Vaginal tightness test before any subsequent treatment.<\/li>\n<li>Before using the device, sterilize and wipe the Vaginal handle and the Vaginal Cartridges by using alcohol or non-corrosive antiseptics. This is important to prevent cross infections. Insert the 4.5 mm cartridge first.<\/li>\n<li>Insert a condom to avoid direct contact of the Vagina with the cartridge and handle. Despite the use of a condom it essential to sterilize well the cartridges and handle in advance.<\/li>\n<li>Set up the unit according to the number of shots per angle rotation etc.\u00a0 Select the lowest power setting which is then to be adjusted up.<\/li>\n<li>Before inserting the vaginal handle place the abundant amount of appropriate Vaginal Lubricant to facilitate insertion and also ultrasonic conductivity.<\/li>\n<li>Insert the handle into the Vagina up until reaching the cervix entrance. In order to do this appropriately, insert the handle gently and slowly. Always ask the subject whether she is still comfortable while you are inserting the handle very slowly, if the client shows signs of discomfort, stop immediately and if you have not encountered resistance yet, wait and continue to insert the handle slowly until you notice find some resistance. Only push very gently and always watch for the subject comfort while inserting the handle.\u00a0 When you have reached some degree of resistance pull the handle 5 to 7 mm and start the procedure by pressing the start button on the handle. The handle will automatically start rotating and firing the shots.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<figure id=\"attachment_2528\" class=\"wp-caption aligncenter\" style=\"width: 600px;\" aria-describedby=\"caption-attachment-2528\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" class=\"wp-image-2528 size-full\" src=\"https:\/\/i0.wp.com\/areton-ltd.com\/wp-content\/uploads\/2017\/11\/20-hifu-vaginal-tightening-machine-03.jpg?resize=600%2C600\" srcset=\"https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/20-hifu-vaginal-tightening-machine-03.jpg?w=600&amp;ssl=1 600w, https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/20-hifu-vaginal-tightening-machine-03.jpg?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/20-hifu-vaginal-tightening-machine-03.jpg?resize=100%2C100&amp;ssl=1 100w, https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/20-hifu-vaginal-tightening-machine-03.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/areton-ltd.com\/Aretonoldbackup\/wp-content\/uploads\/2017\/11\/20-hifu-vaginal-tightening-machine-03.jpg?resize=400%2C400&amp;ssl=1 400w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<p>Basic pictorial representation of the HIFU Vaginal tightening treatment .[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text]<\/p>\n<ul>\n<li>At the very beginning of the treatment, after the first one or two shots pause the treatment and increase the power level. Ask the Subject weather she is still comfortable and keep increasing the power level up to when the subject finds it tolerable, (this is the appropriate power level to be used thought the treatment). If at any point the power level becomes intolerable, turn it down to a tolerable level.<\/li>\n<li>You are supposed to carry out a number of 360 Rotations to complete the treatment with the given cartridge. Once the first 360 degrees rotation has been completed slightly pull out the handle gently. Pull the handle out equal to the length of the ultrasound line (the length of the black part of the cartridge emitting the ultrasound).<\/li>\n<li>Once you pulled the handle in the right position, then fire another full rotation making sure the subject can bear the intensity of the treatment. Repeat the process until you only have to pull the handle out\u00a0off the vagina.<\/li>\n<li>Once you have completed the treatment with the 4.5 Cartridge, remove the condom, remove the previous 4.5 mm Cartridge and insert the 3.0 mm cartridge. Wipe the handle with alcohol or other non-corrosive sterilizer and once dry, insert a new condom and repeat the whole process above.<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;10px&#8221;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/eWgD3SWYygI&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;maintenance-notes&#8221;][vc_column][vc_empty_space][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Notes for use and maintenance<\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<ol>\n<li>For its correct use and warranty purposes only use accessories supplied by Areton Ltd<\/li>\n<li>After use, the device must be wiped and disinfected with an appropriate antiseptic product. Clean cartridges using non-corrosive antiseptic. Alcohol is suitable for this purpose. The cartridges are packaged in an anti-static package, Do not touch the chip.\u00a0\u00a0Cartridges and handle need to keep clean and dry. Put the cartridges into packages for next use after wiping all other accessories using alcohol. In order to avoid breaking or damaging the cartridges, please clean only with alcohol, do not use any other corrosive products solvents.<\/li>\n<li>To power up the unit only use a socket which has active earthing.<\/li>\n<li>Do not use the device close to damp environments or water.<\/li>\n<li>Keep the device away from direct sun exposure and heat sources.<\/li>\n<li>Poor Contact with the skin through the ultrasound conductive gel can cause the cartridges to deteriorate prematurely.<\/li>\n<li>Switch off and unplug the unit after its use.<\/li>\n<\/ol>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Notes for use and maintenance<\/h2>\n<p>[\/vc_column_text][vc_column_text]Drain all cartridges of their water before embarking any aircraft. In the case of air transport, it is highly advisable that the water inside the cartridges be drained before the device embarks the aircraft. Refill the cartridges with distilled water once you have arrived at the destination and you intend to use the device again. Failure to drain the water from the cartridges before embarking the aircraft can cause the breakage of the unit due to the water spilling out of the cartridge. This is due to the difference in pressure caused by the altitude of the aircraft. In any case when transporting the unit always place it inside the original shock-absorbing casing provided.<\/p>\n<p>Note: Water has to be changed every 3 months.\u00a0 Do not need to change the water after the number of shots.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/XHFQKOT3qm8&#8243; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/TSoI6suhWAg&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row][vc_row el_id=&#8221;troubleshooting&#8221;][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2><strong>Contraindications<\/strong><\/h2>\n<p>The subject undergoing HIFU treatment has to be healthy overall.\u00a0 Do not use the device on:<\/p>\n<ul>\n<li>Pregnant women.<\/li>\n<li>Subjects with Heart disease, diabetes, hyperthyroidism.<\/li>\n<li>Subjects with cancer.<\/li>\n<li>Surgical wounds not yet healed.<\/li>\n<li>Subjects who had undergone\u00a0 botulinum toxin injections within one year<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Troubleshooting<\/h2>\n<p>When the cartridge is not placed perpendicular to the face, the device could automatically power off; in this case, restart the unit and place the cartridge perpendicular to the skin of the subject you are treating.<\/p>\n<p>Ths Device intended uses are only Aesthetic, no medical claims are made at any point This device is only intended to improve the lifestyle of the individual and his\/her appearance. No claims of curing disease are made on this device.\u00a0 This instruction manual provides a description of this HIFU System, its controls and displays. Instructions for its basic operation and other information important to the user. Detailed clinical use of the device is provided separately. The Information in this manual is intended solely for the devices manufactured by Areton Ltd and Areton Ltd\u2019s Clients.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Hifu Vaginal Rejuvenation<\/h2>\n<p>[\/vc_column_text][vc_empty_space][vc_video link=&#8221;https:\/\/youtube.com\/embed\/eWgD3SWYygI&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2>Body Treatment<\/h2>\n<p>[\/vc_column_text][vc_empty_space][vc_video link=&#8221;https:\/\/youtube.com\/embed\/vQ3Qz4O-wHk&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h2>Device Tour<\/h2>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;70px&#8221;][vc_video link=&#8221;https:\/\/youtube.com\/embed\/Fib0XSAoM_c&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h2>Body treatment demonstration<\/h2>\n<p>[\/vc_column_text][vc_empty_space][vc_video link=&#8221;https:\/\/youtube.com\/embed\/FAhQosm9eYE&#8221; size=&#8221;500&#8243; height_size=&#8221;400&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space][vc_single_image image=&#8221;7215&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; style=&#8221;vc_box_outline&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/areton-ltd.com\/product\/3-in-1-hifu\/&#8221;][vc_empty_space][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;6390&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/areton-ltd.com\/quiz\/3-in-1\/&#8221;][vc_btn title=&#8221;Take Test now and get your certification&#8221; color=&#8221;danger&#8221; size=&#8221;lg&#8221; align=&#8221;center&#8221; link=&#8221;url:http%3A%2F%2Fareton-ltd.com%2Fquiz%2F3-in-1%2F|||&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;6295&#8243; img_size=&#8221;full&#8221; style=&#8221;vc_box_outline&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/www.youtube.com\/channel\/UCAKMKWmwxEVL74f5szpnLUg\/videos&#8221;][vc_single_image image=&#8221;6297&#8243; img_size=&#8221;full&#8221; style=&#8221;vc_box_outline&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;http:\/\/areton-ltd.com\/contact\/&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][vc_column_text] Table Content Content Links Warnings and Disclaimer Read More Device Main Parameters Read More Main Unit Front and Back Introduction [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"plain-container","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2410","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/pages\/2410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/comments?post=2410"}],"version-history":[{"count":144,"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/pages\/2410\/revisions"}],"predecessor-version":[{"id":7894,"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/pages\/2410\/revisions\/7894"}],"wp:attachment":[{"href":"https:\/\/areton-ltd.com\/Aretonoldbackup\/wp-json\/wp\/v2\/media?parent=2410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}